When an H2S leak occurs upwind of your location, the safest direction for you to go is:
Further downwind, to the muster point
Climb up the nearest tower
A crosswind path to the muster point
Remain where you are
Q.4
An H2S concentration of ______ ppm or greater is considered to be Immediately Dangerous to Life and Health (IDLH), and will start to cause a loss of smell and irritation to the eyes, nose, and lungs
100 ppm
1000 ppm
50 ppm
200 ppm
Q.5
The melting point of pure sulfur is ______ , while the ignition temperature is ______.
150°C (300°F), and 350°C (660°F)
119°C (246°F), and 249°C (480°F)
140°C (284°F), and 260°C (500°F)
110°C (230°F), and 220°C (428°F)
Q.6
In the Claus Reaction Furnace, a portion ( ) of the H2S is burned to make SO2, this allows for an H2S:SO2 ratio of ______ , which is optimal for the Claus reaction in the converters.
1/4, 3:1
2/3, 1:2
1/3, 2:1
1/2, 1:1
Q.7
For sulfuric chemical equilibrium reactions there are several factors that may influence their completeness and resulting sulfur production. These do NOT include:
Piping size
Temperature of the reaction
Concentration of H2S and SO2
Pressure of the reaction
Q.8
The air demand signal should oscillate between ______ percent on the DCS system. An oscillation larger than this will result in a loss in the overall recovery efficiency of the SRU.
+/- 5.0
+/- 1.0
+/- 0.1
+/- 0.5
Q.9
The reaction furnace temperature should be kept above ________ °C to ensure complete destruction of contaminants like BTEX, Mercaptans, and Hydrogen Cyanide..
900°C (1650°F)
1050°C (2000°F)
1250°C (2280°F)
1550°C (2820°F)
Q.10
In the reaction furnace, a state of deficient air by the Air Demand Analyzer would result in:
Excess SO2 produced and an increased ratio
Excess SO2 produced and a decreased ratio
Excess H2S produced and an increased ratio
Excess H2S produced and a decreased ratio
Q.11
The preferred method for reheating in an SRU is ____________ because no extra components are added to the process stream.
Indirect Fired Reheaters
Direct Fired Reheaters
Hot Gas Bypass
Steam Tracing/Steam Jackets
Q.12
When starting up an SRU, the rate of increase in reaction furnace temperature should be ______ , except for the first 300°C after ignition.
20°C (70°F) per hour
40°C (100°F) per hour
80°C (175°F) per hour
100°C (210°F) per hour